Generator set load sharing

Generator set load sharing

(1)Application

SY-SC-2042/2043 load sharing modules allow for kilowatt electrical load to be proportionally shared between two or more generator sets while the system frequency is held constant. An internal On load circuit maximises performance in single or parallel operation

 

(2)Characteristics:

High adjustment precision, low temperature draft

Automatic load sharing

Load unbalanced “ scale” adjustment

On load “differential coefficient” adjustment

Forward power protection( relay output, manual / automatic reset)

Reverse power protection( relay output, manual / automatic reset)

Active power simulate value output and checkup.

 

(3) Technical parameters

Battery voltage

10 ~ 30V DC

Power sampling frequency

50/60?400Hz?selectable

Power sampling current signal

3 phase 0~5A

Forward power protection range

relay outputON20~120 %

relay outputOFF0~80 %

Reverse power protection range

relay output“ON”1~20 %

Active load balance adjustment

more than±2 %

Battery voltage

10 ~16 or 15~ 30V DC